A new electronic circuit for a hot-cathode ionization gauge
J. Schutten, A new electronic circuit for a hot-cathode ionization gauge, Appl. Sci. Res. B 6, 276-284, (1956)
The ion source of the Amsterdam isotope separator
J. Kistemaker, P.K. Rol, J. Schutten, C. Vries, The ion source of the Amsterdam isotope separator, Z. Naturforsch. Teil A 10, 850-856, (1955)
Elektromagnetische Trennung von Isotopen
J. Kistemaker, Elektromagnetische Trennung von Isotopen, Physikertag. Wiesbaden, 63-72, (1955)
Charge exchange and ionization cross-section determination for positive ions and atoms in the energy region 2.5 to 25 KeV
F.J. Heer, W. Huizinga, J. Kistemaker, Charge exchange and ionization cross-section determination for positive ions and atoms in the energy region 2.5 to 25 KeV, Appl. Sci. Res. B 5, 337-339, (1955)
Potential distribution in magnetic arc discharges
J. Kistemaker, Potential distribution in magnetic arc discharges, Appl. Sci. Res. B 5, 313-317, (1955)
De stand van de precisie massaspectrografie
J. Kistemaker, De stand van de precisie massaspectrografie, NTvN 21, 219-229, (1955)
The enrichment of radio-active isotopes by thermal diffusion
A.E. Vries, The enrichment of radio-active isotopes by thermal diffusion, Physica 21, 124-126, (1955)
An electromagnetic isotope separator
C.J. Zilverschoon, An electromagnetic isotope separator, (1954)
The anti-contamination circuit of the Amsterdam isotope separator. I
J. Schutten, C.J. Zilverschoon, J. Kistemaker, The anti-contamination circuit of the Amsterdam isotope separator. I, Appl. Sci. Res. B 4, 217-224, (1954)
De electromagnetische scheiding van isotopen. De Amsterdamse isotopen separator
J. Kistemaker, C.J. Zilverschoon, J. Schutten, De electromagnetische scheiding van isotopen. De Amsterdamse isotopen separator, NTvN 20, 5-11, (1954)
Quelques méthodes d’isolement des isotopes
J. Kistemaker, Quelques méthodes d'isolement des isotopes, (1954)
The anti-contamination circuit of the Amsterdam isotope separator. II
J. Schutten, The anti-contamination circuit of the Amsterdam isotope separator. II, Appl. Sci. Res. B 4, 225-234, (1954)
De electromagnetische scheiding van stabiele isotopen II: de Amsterdamse isotopen separator
J. Kistemaker, C.J. Zilverschoon, J. Schutten, De electromagnetische scheiding van stabiele isotopen II: de Amsterdamse isotopen separator, Elektro-Techniek 32, (1954)
Detection of thermal neutrons by borazole filled proportional counters
A.E. Vries, H. Jansz, J. Kistemaker, H.C. Hamers, J. Blok, C.C. Jonker, Detection of thermal neutrons by borazole filled proportional counters, Physica 20, 1138-1140, (1954)
Some mass spectrometrical possibilities in the high mass range of organic molecules
J. Kistemaker, Some mass spectrometrical possibilities in the high mass range of organic molecules, (1953)
The influence of fractionizing and viscosity effects in mass spectrometric gas handling systems
J. Kistemaker, The influence of fractionizing and viscosity effects in mass spectrometric gas handling systems, (1953)
A high-intensity electromagnetic isotope separator
J. Kistemaker, C.J. Zilverschoon, A high-intensity electromagnetic isotope separator, (1953)
De electromagnetische scheiding van stabiele isopen I
J. Kistemaker, C.J. Zilverschoon, J. Schutten, De electromagnetische scheiding van stabiele isopen I, Elektro-Techniek 31, (1953)
Some measurements on a not selfsustaining gas discharge with an axial magnetic field
J. Kistemaker, J. Snieder, Some measurements on a not selfsustaining gas discharge with an axial magnetic field, Physica 19, 950-960, (1953)